WT1800E High-performance Power Analyzer

WT1800E High-performance Power Analyzer

Description

Send us your enquiry
Category:

Product Description

The WT1800E is a high-performance Yogokawa power analyzer it gives power accuracy of 0.05% of reading plus 0.05% of range. It is capable of harmonics analysis up to the 500th order of a 50/60 Hz fundamental frequency. With up to 6 input channels, a wide range of display and analysis features, and PC connectivity, the WT1800E is the ideal tool  to accurately measure the power characteristics and efficiency of electrical devices

Standard FeaturesOptional Features

  1. External Media Slot
  2. Element Setting
  3. U/I range display
  4. Display Settings
  5. Measurement item selection
  6. Integration Settings
  7. Data Saving
  8. Built-in Printer (/B5 Option)

WT1800E high-performance yogokawa power analyzer

Current Sensor Power (/PD2 Option)

DETAILS

Provides Complete System Measurement Needs

  • Simultaneous Electrical Power Measurements of up to 6 Voltages and 6 Currents at 2MS/s (16 bits)
  • Mechanical parameters such as Rotational Speed & Direction, Torque, Slip, Electrical Angle, Mechanical Power, and Motor efficiency

 Guaranteed Accuracy

  • Basic Power Accuracy of 0.05% of reading +/- 0.05% of range, guaranteed from 1% to 110% of the selected range
  • Direct Inputs for Voltage & Current, plus an External Input for Sensor connections

Independent Range Configuration with Selective Auto-ranging for repetitive production testing

No Unwanted Harmonics

  • Analyze up to 500th order of Harmonics for 50/60Hz fundamental signals
  • Multiple harmonic parameters such as THD, HDF, THF, and Impedance
  • Dual Harmonic feature to analyze both input and output of inverters
  • Basic power accuracy:
    • 05% of reading
    • 05% or range
  • Up to 6 input channels at 2 MS/s (16 bits)

6 inputs on a high-resolution display

Make simultaneous measurements on up to 6 inputs at 2 MS/s (16 bits). The high-resolution 8.4-inch XGA display of the WT1800E Yogokawa  allows split screen viewing of up to 6 waveforms and can display up to 12 pages of diverse measurement parameters making it ideal for efficiency tests of inverter-driven motors, renewable energy technologies, and traction applications like pumps, fans, and hybrid/electric vehicles. The unit can also display measurements in vector format or trending in time.

Guaranteed accuracy across a wide range

Measure accurately at a wide range of voltage, current, and frequency conditions. The basic power accuracy of the WT1800E Yogokawa power analyzer is between 1% to 110% of the selected voltage and current range. This equates to voltages from 15 mV to 1100 V RMS and currents from 0.1 mA to 5.5 A RMS (for a 5 A input element) and 10 mA to 55 A RMS (for a 50 A input element). The unit is also accurate during large phase shifts and high frequencies thanks to the minimized influence of the low power factor error (±0.07% of apparent power).

Range configuration

Track signal changes faster by eliminating unnecessary range changes. The WT1800E’s range configuration function allows users to select input ranges based on their specific use cases so that optimal range settings are achieved quicker. This reduces the time during repetitive production tests, such as setting to OFF, 100 V, OFF, and so on, which are performed frequently on the production line.

Harmonic analysis

Analyze harmonics up to the 500th order for a 50/60 Hz fundamental even at a data update interval of 50 milliseconds. The WT1800E features two options for analyzing harmonics in addition to power parameters.

  • Harmonic measurement mode (/G5 option) for fundamental wave, harmonic components, and total harmonic distortion (THD)
  • Dual Harmonic option (/G6 option) for side-by-side measurement of harmonics on two different sources for example input and output of inverters, variable speed motors, lighting ballasts, UPS, etc.

Power integration and auto ranging

  • Measure energy bought/sold grid connections or charged/discharged in batteries. The WT1800E’s Power integration function integrates instantaneous values for both positive and negative readings. It also measures total energy (Wh) and current (Ah) when load conditions vary widely such as in devices transitioning from standby to operation mode. Should an input signal start to fall out of the expected range, this function can automatically adjust the range while continuing to integrate the measured values.

High-speed data capture

The high-speed data capturing function can measure Sigma-Urms, Sigma-Irms, and Sigma-P from DC signal and three phase devices every 5 ms when External Synchronization is OFF. It can also update at 1 ms to 100 ms when External Synchronization is ON depending on the frequency of the clock signal.

Flexible & automatic data updates

Manually or automatically set measurement intervals. The WT1800E Yogokawa Power Analyzer offers 9 data update intervals between 50 ms to 20 s but can also follow fluctuating input frequencies by changing the data update rate automatically. This is useful when measuring devices like motors whose input signal frequency varies with RPM.

measurment yogokawa power analyzer

DC power supply for AC/DC current sensors (/PD2 option)

  • The WT1800E yogokawa power analyzer can be equipped with a DC power supply for the CT series of AC/DC current sensors. By using dedicated connection cables and shunt resistors, the WT1800E can measure large currents. Improved S/N ratio and noise immunity is achieved by connecting the sensors in this way.
  • /EX1 to /EX6 option must be installed in the WT1800E to be able to use the Shunt Resistor Box.

Motor evaluation function

Measure more than just electrical parameters. The motor evaluation function enables the measurement of rotation speed and direction, torque, mechanical power, synchronous speed, slip, electrical angle, motor efficiency, and total system efficiency from the analog or pulse outputs of rotation and torque sensors.

761941 WTViewerE Application Software for Yokogawa Power Analyzer WT3000E/ WT3000/ WT1800E/ WT1800/ WT500/ WT300E/ WT300

WTViewerE software enables PC connectivity for Yokogawa power analyzer such as the WT3000E, WT1800E, WT500, and WT300E through Ethernet, USB, GPIB, or RS232. This connectivity allows users to easily control, monitor, collect, analyze, and save measurements remotely.

WTViewerEfree application software

  • Easily view, control, and download measurements from your PC. The WTViewerEfree is free software that connects the WT1800E Yogokawa Power Analyzer to a PC via a communications interface making numeric, waveform, trend, and harmonic data easily accessible via PC.

wtview yogokawa power analyzer

User-defined events and computations

  • The event trigger function of the Yokogawa Power Analyzer WT1800E allows users to set limits for the capture of readings that fall into or out of a specific range of power, current or other parameters. Data that meets the trigger conditions are stored, printed, saved to a USB memory device, etc. Users can also define and use up to 20 expressions for custom calculations.

Two types of Input Elements of  Yogokawa Power Analyzer

Basic Power Accuracy: ±(0.05% of reading + 0.05% of range)*1
Measurement Bandwidth: DC, 0.1 Hz to 1 MHz
Low Power Factor Error: Power factor influence when cosø = 0

  1. 07% of S
    S is reading the value of apparent power
    ø is the phase angle between voltage and current

Temperature range: 23 ±5˚C
Current Range:

  • Direct Input: 1/2/5/10/20/50 A*2
    • 10/20/50/100/200/500 mA, 1/2/5 A*2(50 A and 5 A input elements can be installed together)
  • External Input: 50/100/200/500 mV, 1/2/5/10 V*2

Voltage Range: 1.5/3/6/10/15/30/60/100/150/300/600/1000 V*2
Effective input range: 1% to 110%
Data Update Interval: 50 ms to 20 s or Auto

Reviews

There are no reviews yet.

Be the first to review “WT1800E High-performance Power Analyzer”

Your email address will not be published. Required fields are marked *