0-630V DC Power Supply

0-630V DC Power Supply

Description

Features:

  • Programmable and reading accuracy condition:(25℃±5℃)
  • Load change from 100% to 5%or 50% to 100%, the time for output voltage returning to “rated value ±100mV”
  • Temperature drifts: output voltage change rate is caused by temperature change under power supply using condition
  • Time drifts: output voltage change rate is caused by working more than 8 hours
Send us your enquiry

Product Description

Technical specification: 630V DC Power Supply

Dc Power Supply 0-630v

Model 50805(F) 50810(F)
Input 3-phase,3-line
380V±40V,50Hz±5Hz
Output Voltage 0-630V
Current 0-25A 0-50A
Power 0-15kVA 0-30kVA
Display LCD,4 digits
Setting Accuracy Voltage (100V-630V):≤±1%*reading
(6V-100V):≤±1%*reading±1V
Current ≤±1% (reading + measurement)
Read Back Accuracy Voltage (100V-630V):≤±1%*reading
(6V-100V):≤±1%*reading±1V
Current ≤±1% (reading + measurement)
Ripple & Noise
20Hz-20MHz
Vrms 350mV
Vpp 900mV
Power Voltage Effect ±0.2%
Load Effect ±0.2%
Noise ≤65db(A) ≤70db(A)
Efficiency ≥ 0.85
Overload 105%<rated current<1200%, the output will be stopped within 5s.
200%< rated current, the output will be stopped immediately
Protection Function Input lack phase protection(three-phase);
Output over-current/over-voltage protection; inverted and short circuit protection;
Overheat protection
Transient Response Time ≤10ms
Max. Lead Wire Voltage Drop Compensation 15V
Communication Function RS232(standard)/RS485(Optional)
Memory Function Can preset 10 groups parameters
Measurement Function 5 setting groups and 10 steps sequence,3 working modes for every step, max cycle3000 times
Temperature Drifts 0.04%Vmax/℃
Time Drifts 0.3%Vmax
Working Conditions Operating Temperature:0℃-40℃; Operating Humidity:10-95%
Dimension
W×H×D(mm)
550×1200×660
Weight 240kg
Remarks 630V DC Power Supply Programmable and reading accuracy condition:(25℃±5℃)
Load change from 100% to 5%or 50% to 100%, the time for output voltage returning to “rated value ±100mV”
Temperature drifts: output voltage change rate is caused by temperature change under power supply using condition
Time drifts: output voltage change rate is caused by working more than 8 hours

Reviews

There are no reviews yet.

Be the first to review “0-630V DC Power Supply”

Your email address will not be published. Required fields are marked *