<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>AC/DC POWER SUPPLY &#8211; Technical Products</title>
	<atom:link href="https://technicalproducts.in/product-category/ac-dc-power-supply/feed/" rel="self" type="application/rss+xml" />
	<link>https://technicalproducts.in</link>
	<description>Technical Products</description>
	<lastBuildDate>Fri, 25 Apr 2025 06:01:12 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.4</generator>

<image>
	<url>https://technicalproducts.in/wp-content/uploads/2022/06/technical-logo-100x100.png</url>
	<title>AC/DC POWER SUPPLY &#8211; Technical Products</title>
	<link>https://technicalproducts.in</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Frecquency Converter Power Supply — 97 Single Phase</title>
		<link>https://technicalproducts.in/product/frecquency-converter-power-supply-97-single-phase/</link>
					<comments>https://technicalproducts.in/product/frecquency-converter-power-supply-97-single-phase/#respond</comments>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Fri, 01 Jul 2022 11:56:35 +0000</pubDate>
				<guid isPermaLink="false">https://technicalproducts.in/?post_type=product&#038;p=7342</guid>

					<description><![CDATA[<p>The systems can be used to test PC/Servo/Telecom power supplies, adapters, chargers, backlight inverters, LED power drivers, UPS’s, PV Inverters, and EV chargers.</p>
<p><strong>Input power：</strong> Single phase 200V±15% &#124; 3-phase 4-wires/3×220V±15%</p>
<p><strong>Output capacity：</strong>500VA 1kVA 2kVA 3kVA 5KVA 10kVA</p>
<p><strong>Output Current：</strong>110V(4.6A 9.2A 18.2A 27.4A 45.6A 91A) &#124; 220V(2.3A 4.6A 9.1A 13.7A 22.8A 45.5A)</p>
<p>The post <a rel="nofollow" href="https://technicalproducts.in/product/frecquency-converter-power-supply-97-single-phase/">Frecquency Converter Power Supply — 97 Single Phase</a> appeared first on <a rel="nofollow" href="https://technicalproducts.in">Technical Products</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h3>Frequency Converter Power Supply — 97 Single phase​</h3>
<p>The Frequency Converter Power Supply systems can be used to test PC/Servo/Telecom <strong><a href="https://technicalproducts.in/data-logger/">Power Supplies</a></strong>, adapters, chargers, backlight inverters, LED power drivers, UPSs, PV Inverters, and EV chargers.</p>
<div>
<table class="table table-bordered" width="627">
<tbody>
<tr>
<td width="131"><strong>Type</strong></td>
<td width="237"><strong>AN97H series</strong></td>
<td colspan="2" width="259"><strong>AN97TS series</strong></td>
</tr>
<tr>
<td width="131"><strong>Input power</strong></td>
<td width="237"><strong>Single-phase 200V±15%</strong></td>
<td colspan="2" width="259"><strong>3-phase 4-wires/3×220V±15%</strong></td>
</tr>
<tr>
<td width="131"><strong>Output phase</strong></td>
<td colspan="3" width="496"><strong>Single Phase</strong></td>
</tr>
<tr>
<td width="131"><strong>Output voltage</strong></td>
<td colspan="3" width="496"><strong>Auto:(Low gear)1~150.0V,(High gear)150.1~300.0V Hold:(high gear)1~300V</strong></td>
</tr>
<tr>
<td width="131"><strong>Output frequency</strong></td>
<td colspan="3" width="496"><strong>45~65Hz continuous, adjustable</strong></td>
</tr>
<tr>
<td width="131"><strong>Distortion</strong></td>
<td colspan="3" width="496"><strong>2%</strong></td>
</tr>
<tr>
<td width="131"><strong>Frequency stability</strong></td>
<td colspan="3" width="496"><strong>0.1%</strong></td>
</tr>
<tr>
<td width="131"><strong>Power effect</strong></td>
<td colspan="3" width="496"><strong>1%</strong></td>
</tr>
<tr>
<td width="131"><strong>Voltage stability</strong></td>
<td colspan="3" width="496"><strong>≤1%</strong></td>
</tr>
<tr>
<td width="131"><strong>Load effect</strong></td>
<td colspan="3" width="496"><strong>1%</strong></td>
</tr>
<tr>
<td width="131"><strong>Transient recover time</strong></td>
<td colspan="3" width="496"><strong>20ms</strong></td>
</tr>
<tr>
<td width="131"><strong>Over-current protection</strong></td>
<td colspan="3" width="496"><strong>1.05 rate</strong></p>
<p><strong>1.1 rated</strong></td>
</tr>
<tr>
<td width="131"><strong>Protection mode</strong></td>
<td colspan="3" width="496"><strong>Short-circuit, overload, and power device overheat protection</strong></td>
</tr>
<tr>
<td width="131"><strong>Loading capacity</strong></td>
<td colspan="3" width="496"><strong>Can Start an inductive load whose capacity is less than 0.5 rated power</strong></p>
<p><strong>The capacity of AC power supply, or rectifier load which crest factor is less than 3.0</strong></td>
</tr>
<tr>
<td width="131"><strong>Memory function</strong></td>
<td colspan="3" width="496"><strong>Save the settings before turning off</strong></td>
</tr>
<tr>
<td width="131"><strong>Shortcut group</strong></td>
<td colspan="3" width="496"><strong>6 groups</strong></td>
</tr>
<tr>
<td width="131"><strong>Preset function</strong></td>
<td colspan="3" width="496"><strong>The output voltage, output frequency, and output voltage tolerance can be preset under standby status</strong></td>
</tr>
<tr>
<td width="131"><strong>Adjustment online</strong></td>
<td colspan="3" width="496"><strong>Under running status, the output voltage can be adjustable through the “+” or”-“button</strong></td>
</tr>
<tr>
<td width="131"><strong>Voltage</strong></td>
<td colspan="3" width="496"><strong>Resolution:0.1V Accuracy: ±(0.8%×reading +0.2%×range)</strong></td>
</tr>
<tr>
<td width="131"><strong>Current</strong></td>
<td colspan="2" width="255"><strong>Resolution:0.001A/0.01A</strong></p>
<p><strong>Accuracy: ±(2%×reading+1%×rated output)</strong></td>
<td width="241"><strong>Resolution: 0.01A</strong></p>
<p><strong>Accuracy: ±(2%×reading+1%×rated output)</strong></td>
</tr>
<tr>
<td width="131"><strong>Power</strong></td>
<td colspan="2" width="255"><strong>Resolution:0.001KW/0.01KV</strong></p>
<p><strong>Accuracy: ±5%</strong></td>
<td width="241"><strong>Resolution: 0.01KV</strong></p>
<p><strong>Accuracy: ±5%</strong></td>
</tr>
<tr>
<td width="131"><strong>Display</strong></td>
<td colspan="2" width="255"><strong>VFD</strong></td>
<td width="241"><strong>LED 4-windows</strong></td>
</tr>
<tr>
<td width="131"><strong>Communication</strong></td>
<td colspan="3" width="496"><strong>Standard:RS232,Optional:RS485,Remote Control</strong></td>
</tr>
<tr>
<td width="131"></td>
<td width="237"></td>
<td width="18"></td>
<td width="241"></td>
</tr>
</tbody>
</table>
</div>
<p>&nbsp;</p>
<p><strong>Input power：</strong> Single phase 200V±15% | 3-phase 4-wires/3×220V±15%</p>
<p><strong>Output capacity：</strong>500VA 1kVA 2kVA 3kVA 5KVA 10kVA</p>
<p><strong>Output Current：</strong>110V(4.6A 9.2A 18.2A 27.4A 45.6A 91A) | 220V(2.3A 4.6A 9.1A 13.7A 22.8A 45.5A)</p>
<p>The post <a rel="nofollow" href="https://technicalproducts.in/product/frecquency-converter-power-supply-97-single-phase/">Frecquency Converter Power Supply — 97 Single Phase</a> appeared first on <a rel="nofollow" href="https://technicalproducts.in">Technical Products</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://technicalproducts.in/product/frecquency-converter-power-supply-97-single-phase/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>0-630V DC Power Supply</title>
		<link>https://technicalproducts.in/product/0-630v-dc-power-supply-2/</link>
					<comments>https://technicalproducts.in/product/0-630v-dc-power-supply-2/#respond</comments>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Fri, 01 Jul 2022 11:53:34 +0000</pubDate>
				<guid isPermaLink="false">https://technicalproducts.in/?post_type=product&#038;p=7341</guid>

					<description><![CDATA[<p><strong>Features:</strong></p>
<ul>
<li>Programmable and reading accuracy condition:(25℃±5℃)</li>
<li>Load change from 100% to 5%or 50% to 100%, the time for output voltage returning to “rated value ±100mV”</li>
<li>Temperature drifts: output voltage change rate is caused by temperature change under power supply using condition</li>
<li>Time drifts: output voltage change rate is caused by working more than 8 hours</li>
</ul>
<p>The post <a rel="nofollow" href="https://technicalproducts.in/product/0-630v-dc-power-supply-2/">0-630V DC Power Supply</a> appeared first on <a rel="nofollow" href="https://technicalproducts.in">Technical Products</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2 class="elementor-heading-title elementor-size-default">Technical specification: <strong>630V DC <a href="https://technicalproducts.in/ac-dc-power-supply/">Power Supply</a></strong></h2>
<p><strong><a href="https://technicalproducts.in/ac-dc-power-supply/">Dc Power Supply 0-630v</a></strong></p>
<div>
<table class="table table-bordered" width="550">
<tbody>
<tr>
<td colspan="2"><strong>Model</strong></td>
<td><strong>50805(F)</strong></td>
<td><strong>50810(F)</strong></td>
</tr>
<tr>
<td colspan="2"><strong>Input</strong></td>
<td colspan="2">3-phase,3-line<br />
380V±40V，50Hz±5Hz</td>
</tr>
<tr>
<td rowspan="3"><strong>Output</strong></td>
<td>Voltage</td>
<td colspan="2">0-630V</td>
</tr>
<tr>
<td>Current</td>
<td>0-25A</td>
<td>0-50A</td>
</tr>
<tr>
<td>Power</td>
<td>0-15kVA</td>
<td>0-30kVA</td>
</tr>
<tr>
<td><strong>Display</strong></td>
<td></td>
<td colspan="2">LCD,4 digits</td>
</tr>
<tr>
<td rowspan="2"><strong>Setting Accuracy</strong></td>
<td>Voltage</td>
<td colspan="2">(100V-630V):≤±1%*reading<br />
(6V-100V):≤±1%*reading±1V</td>
</tr>
<tr>
<td>Current</td>
<td colspan="2">≤±1% (reading + measurement)</td>
</tr>
<tr>
<td rowspan="2"><strong>Read Back Accuracy</strong></td>
<td>Voltage</td>
<td colspan="2">(100V-630V):≤±1%*reading<br />
(6V-100V):≤±1%*reading±1V</td>
</tr>
<tr>
<td>Current</td>
<td colspan="2">≤±1% (reading + measurement)</td>
</tr>
<tr>
<td rowspan="2"><strong>Ripple &amp; Noise<br />
20Hz-20MHz</strong></td>
<td>Vrms</td>
<td colspan="2">350mV</td>
</tr>
<tr>
<td>Vpp</td>
<td colspan="2">900mV</td>
</tr>
<tr>
<td colspan="2"><strong>Power Voltage Effect</strong></td>
<td colspan="2">±0.2%</td>
</tr>
<tr>
<td colspan="2"><strong>Load Effect</strong></td>
<td colspan="2">±0.2%</td>
</tr>
<tr>
<td colspan="2"><strong>Noise</strong></td>
<td>≤65db(A)</td>
<td>≤70db(A)</td>
</tr>
<tr>
<td colspan="2"><strong>Efficiency</strong></td>
<td colspan="2">≥ 0.85</td>
</tr>
<tr>
<td colspan="2"><strong>Overload</strong></td>
<td colspan="2">105%&lt;rated current&lt;1200%, the output will be stopped within 5s.<br />
200%&lt; rated current, the output will be stopped immediately</td>
</tr>
<tr>
<td colspan="2"><strong>Protection Function</strong></td>
<td colspan="2">Input lack phase protection(three-phase);<br />
Output over-current/over-voltage protection; inverted and short circuit protection;<br />
Overheat protection</td>
</tr>
<tr>
<td colspan="2"><strong>Transient Response Time</strong></td>
<td colspan="2">≤10ms</td>
</tr>
<tr>
<td colspan="2"><strong>Max. Lead Wire Voltage Drop Compensation</strong></td>
<td colspan="2">15V</td>
</tr>
<tr>
<td colspan="2"><strong>Communication Function</strong></td>
<td colspan="2">RS232(standard)/RS485(Optional)</td>
</tr>
<tr>
<td colspan="2"><strong>Memory Function</strong></td>
<td colspan="2">Can preset 10 groups parameters</td>
</tr>
<tr>
<td colspan="2"><strong>Measurement Function</strong></td>
<td colspan="2">5 setting groups and 10 steps sequence,3 working modes for every step, max cycle3000 times</td>
</tr>
<tr>
<td colspan="2"><strong>Temperature Drifts</strong></td>
<td colspan="2">0.04%Vmax/℃</td>
</tr>
<tr>
<td colspan="2"><strong>Time Drifts</strong></td>
<td colspan="2">0.3%Vmax</td>
</tr>
<tr>
<td colspan="2"><strong>Working Conditions</strong></td>
<td colspan="2">Operating Temperature:0℃-40℃; Operating Humidity:10-95%</td>
</tr>
<tr>
<td colspan="2"><strong>Dimension<br />
W×H×D(mm)</strong></td>
<td colspan="2">550×1200×660</td>
</tr>
<tr>
<td colspan="2"><strong>Weight</strong></td>
<td colspan="2">240kg</td>
</tr>
<tr>
<td colspan="2">Remarks</td>
<td colspan="2">630V DC Power Supply Programmable and reading accuracy condition:(25℃±5℃)<br />
Load change from 100% to 5%or 50% to 100%, the time for output voltage returning to “rated value ±100mV”<br />
Temperature drifts: output voltage change rate is caused by temperature change under power supply using condition<br />
Time drifts: output voltage change rate is caused by working more than 8 hours</td>
</tr>
</tbody>
</table>
</div>
<p>The post <a rel="nofollow" href="https://technicalproducts.in/product/0-630v-dc-power-supply-2/">0-630V DC Power Supply</a> appeared first on <a rel="nofollow" href="https://technicalproducts.in">Technical Products</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://technicalproducts.in/product/0-630v-dc-power-supply-2/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Grid simulator Analog AC Power</title>
		<link>https://technicalproducts.in/product/grid-simulator-analog-ac-power/</link>
					<comments>https://technicalproducts.in/product/grid-simulator-analog-ac-power/#respond</comments>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Fri, 01 Jul 2022 08:36:26 +0000</pubDate>
				<guid isPermaLink="false">https://technicalproducts.in/?post_type=product&#038;p=7152</guid>

					<description><![CDATA[<p><strong>Grid simulator Analog AC Power​ :</strong></p>
<ul>
<li>Using FPGA digital control technology, the inverter test process can be fully intelligent;</li>
<li>High-performance low (zero) voltage ride through;</li>
<li>The voltage and frequency can be set to complex programming methods such as steps, steps, or gradations, to easily achieve over-under-voltage and over-under frequency tests;</li>
<li>With harmonic mode, it can superimpose 2 ~ 40th harmonic;</li>
<li>Three-phase unbalance mode, which can adjust three-phase voltage and three-phase phase difference to realize the three-phase unbalance test;</li>
<li>with high-voltage DC output, can form a loop test with the photovoltaic inverter;</li>
<li>3 times the rated current, withstand 2S, strong load capacity;</li>
<li>complete measurement functions: voltage, current, current peak, frequency, active power, apparent power, power factor, voltage crest factor;</li>
</ul>
<p>The post <a rel="nofollow" href="https://technicalproducts.in/product/grid-simulator-analog-ac-power/">Grid simulator Analog AC Power</a> appeared first on <a rel="nofollow" href="https://technicalproducts.in">Technical Products</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><strong><span data-preserver-spaces="true">Product</span></strong><span data-preserver-spaces="true">:- Grid simulator Analog AC Power​</span></p>
<p><strong><span data-preserver-spaces="true">Product Power : </span></strong><span data-preserver-spaces="true">15kva-1000kva</span></p>
<p><strong><span data-preserver-spaces="true">Applications</span></strong><span data-preserver-spaces="true">: household appliances, motors, power tools, switching power supplies, power adapters, UPS, information communications, photovoltaics, lamps, electronic transformers, electronic components, low-voltage power distribution, and other industries.</span></p>
<p><strong><span data-preserver-spaces="true">Enterprise Customers</span></strong><span data-preserver-spaces="true">: National agencies and scientific research institutes such as metrology, quality inspection, commodity inspection, etc. Have won customers’ long-term trust and cooperation from various industries such as Haier, Midea, Gree, Changhong, Hisense, TPV, GE, LG, Philips, Panasonic, and Electrolux. The Grid simulator Analog <strong><a href="https://technicalproducts.in/ac-dc-power-supply/">AC Power</a> </strong>is also exported to many countries and regions in Europe, the United States, South America, Asia, etc.</span></p>
<h3><span data-preserver-spaces="true">Product Details</span></h3>
<p><span data-preserver-spaces="true">Grid simulator Analog AC Power​:</span></p>
<ul>
<li><span data-preserver-spaces="true">Using FPGA digital control technology, the inverter test process can be fully intelligent;</span></li>
<li><span data-preserver-spaces="true">Grid simulator Analog AC Power​ High-performance low (zero) voltage ride through;</span></li>
<li><span data-preserver-spaces="true">The voltage and frequency can be set to complex programming methods such as steps, or gradations, to achieve over-under-voltage and over-under frequency tests easily;</span></li>
<li><span data-preserver-spaces="true">With harmonic mode, it can superimpose 2 ~ 40th harmonic;</span></li>
<li><span data-preserver-spaces="true">Three-phase unbalance mode, which can adjust three-phase voltage and three-phase phase difference to realize the three-phase unbalance test;</span></li>
<li><span data-preserver-spaces="true">Grid simulator Analog AC Power​ with high-voltage DC output can form a loop test with the photovoltaic inverter;</span></li>
<li><span data-preserver-spaces="true">3 times the rated current, withstand 2S, strong load capacity;</span></li>
<li><span data-preserver-spaces="true">complete measurement functions: voltage, current, current peak, frequency, active power, apparent power, power factor, voltage crest factor;</span></li>
<li><span data-preserver-spaces="true">On-line monitoring function: Monitor IGBT temperature, transformer temperature, fan speed, input voltage, and other parameters in the output state;</span></li>
<li><span data-preserver-spaces="true">“Black box” function: automatically record the power state and alarm code when alarming, greatly reducing maintenance time;</span></li>
<li><span data-preserver-spaces="true">Grid simulator Analog AC Power​​ fan speed is automatically adjusted according to the temperature of the power supply to reduce noise;</span></li>
<li><span data-preserver-spaces="true">Lock key, user-friendly design, automatic lock for 5 minutes without operation to prevent misoperation;</span></li>
<li><span data-preserver-spaces="true">8-inch color LCD with exquisite appearance;</span></li>
<li><span data-preserver-spaces="true">Grid simulator Analog AC Power​ Standard RS232, optional RS485, GPIB, Ethernet, and analog control;</span></li>
</ul>
<p>&nbsp;</p>
<h2 class="elementor-heading-title elementor-size-default">Power Grid simulator Analog AC Power​ parameters:</h2>
<p>1000 × 1990 × 8001200 × 1990 × 8001200 × 1990 × 1000</p>
<p>&nbsp;</p>
<table border="1" width="2558" cellspacing="0" cellpadding="0">
<colgroup>
<col span="2" />
<col />
<col />
<col span="4" />
<col span="4" /></colgroup>
<tbody>
<tr>
<td colspan="4">model</td>
<td>GS015T</td>
<td>GS030T</td>
<td>GS045T</td>
<td>GS060T</td>
<td>GS090T</td>
<td>GS120T</td>
<td>GS180T</td>
<td>GS240T</td>
</tr>
<tr>
<td colspan="4">battery capacity</td>
<td>15kVA</td>
<td>30kVA</td>
<td>45kVA</td>
<td>60kVA</td>
<td>90kVA</td>
<td>120kVA</td>
<td>180kVA</td>
<td>240kVA</td>
</tr>
<tr>
<td rowspan="3">AC input</td>
<td colspan="3">Phase</td>
<td colspan="8">Three-phase four-wire + PE</td>
</tr>
<tr>
<td colspan="3">Voltage</td>
<td colspan="8">Phase voltage: 220V ± 33V, line voltage: 380V ± 57V</td>
</tr>
<tr>
<td colspan="3">frequency</td>
<td colspan="8">50 / 60Hz ± 3Hz</td>
</tr>
<tr>
<td rowspan="26">AC output</td>
<td colspan="3">Phase</td>
<td colspan="8">Three-phase four-wire</td>
</tr>
<tr>
<td colspan="3">mode</td>
<td colspan="8">Three-phase standard mode, three-phase unbalanced mode</td>
</tr>
<tr>
<td colspan="3">Voltage</td>
<td colspan="8">Phase voltage: 0.0 ～ 300.0V</td>
</tr>
<tr>
<td colspan="3">frequency</td>
<td colspan="8">45.00 ～ 65.00Hz</td>
</tr>
<tr>
<td colspan="2">Rated current</td>
<td>220V</td>
<td>22.7A</td>
<td>45.4A</td>
<td>68.2A</td>
<td>90.9A</td>
<td>136.3A</td>
<td>181.8A</td>
<td>272.7A</td>
<td>363.6A</td>
</tr>
<tr>
<td colspan="2" rowspan="2">Setting accuracy</td>
<td>Voltage</td>
<td colspan="8">Resolution: 0.1V, accuracy: 0.2% × reading value + 0.2% × full scale value</td>
</tr>
<tr>
<td>frequency</td>
<td colspan="8">Resolution: 0.01Hz, accuracy: 0.05%</td>
</tr>
<tr>
<td colspan="2" rowspan="4">measurement accuracy</td>
<td>Voltage</td>
<td colspan="8">Resolution: 0.1V, accuracy: 0.2% × reading value + 0.2% × full scale value</td>
</tr>
<tr>
<td>frequency</td>
<td colspan="8">Resolution: 0.01Hz, accuracy: 0.05%</td>
</tr>
<tr>
<td>Current</td>
<td colspan="8">Resolution: 0.1A / 1A, accuracy: 0.3% × display value + 0.3% × rated output value</td>
</tr>
<tr>
<td>power</td>
<td colspan="8">Resolution: 0.1kW / 0.01kW / 0.001kW, accuracy: 0.45% × reading value + 0.45% × full-scale value</td>
</tr>
<tr>
<td colspan="3">Frequency stability</td>
<td colspan="8">≤0.02%</td>
</tr>
<tr>
<td colspan="3">Voltage distortion</td>
<td colspan="8">Linear load: THD ＜ 1%</td>
</tr>
<tr>
<td colspan="3">Transient recovery time</td>
<td colspan="8">20ms</td>
</tr>
<tr>
<td colspan="3" rowspan="2">Three-phase phase difference</td>
<td colspan="8" rowspan="2">Three-phase standard mode: 120 ° ± 2 ° Three-phase unbalanced mode: 0.0 ° ～ 359.9 °, 0.1 ° adjustable</td>
</tr>
<tr>
<td colspan="3">Phase voltage crest factor</td>
<td colspan="8">1.41 ± 0.1</td>
</tr>
<tr>
<td colspan="3">Source voltage effect</td>
<td colspan="8">≤1%</td>
</tr>
<tr>
<td colspan="3">Load effect</td>
<td colspan="8">≤1%</td>
</tr>
<tr>
<td colspan="3" rowspan="2">Overload capacity</td>
<td colspan="8" rowspan="2">105% ＜ Output≤110% Shutdown output for 15 seconds; 110% ＜ Output≤200% Shutdown output for 5 seconds; 200% ＜ Output≤300% Shutdown output for 2 seconds; 300% ＜ Output immediately shut down the Output.</td>
</tr>
<tr>
<td colspan="3" rowspan="2">Impact resistance</td>
<td colspan="8" rowspan="2">① It can withstand 3 times of rated current for 2S; ② It can withstand the starting impact of inductive load or crest factor of not more than 3.0 rectifier load with power not more than 0.5 times the rated power of the power supply</td>
</tr>
<tr>
<td colspan="3" rowspan="2">protective device</td>
<td colspan="8" rowspan="2">IGBT overheating, IGBT overcurrent, transformer overheating, input overvoltage, input under-voltage, output overvoltage, output under-voltage, output phase loss, output overcurrent, output overload, output short circuit, bus anti-recharge</td>
</tr>
<tr>
<td colspan="3">effectiveness</td>
<td colspan="8">＞ 86%</td>
</tr>
<tr>
<td rowspan="13">Features</td>
<td colspan="3">Display method</td>
<td colspan="8">8-inch LCD display, resolution: 800 * 600</td>
</tr>
<tr>
<td colspan="3">Output waveform</td>
<td colspan="8">Sine wave, harmonic (superimposed 2 ~ 40th harmonic)</td>
</tr>
<tr>
<td rowspan="4">Programming function</td>
<td colspan="2">Low (zero) voltage ride-through mode</td>
<td colspan="8">Yes, the minimum response time 20ms</td>
<td colspan="2">Step mode</td>
<td colspan="8">9999 stairs</td>
<td colspan="2">Step Mode</td>
<td colspan="8">100 steps 999999 cycles</td>
<td colspan="2">Gradient mode</td>
<td colspan="8">100 steps 999999 cycles</td>
<td colspan="3">Start ramp time</td>
<td colspan="8">0.0 ～ 99.9 seconds</td>
<td colspan="3">Online adjustment function</td>
<td colspan="8">Under normal mode, the output voltage and output frequency can be adjusted online, and the waveform can be switched online</td>
<td colspan="3">memory function</td>
<td colspan="8">Power-down memory function, can remember the last output mode and parameters</td>
<td colspan="3">Shortcut group</td>
<td colspan="8">10 groups in normal mode, 10 groups in harmonics</td>
<td colspan="3">Line voltage drop compensation</td>
<td colspan="8">0.000 ～ 0.500 Euro</td>
<td colspan="3">Communication Interface</td>
<td colspan="8">RS232 (standard), RS485 (optional), GPIB (optional), Ethernet (optional), flip signal (standard)</td>
</tr>
<tr>
<td colspan="3">remote control</td>
<td colspan="8">Analog control port (optional)</td>
</tr>
<tr>
<td rowspan="2">DC output</td>
<td colspan="3">Voltage</td>
<td colspan="8">Actual DC bus voltage</td>
<td colspan="3">Current</td>
<td>16A</td>
<td>33A</td>
<td>49A</td>
<td>65A</td>
<td>98A</td>
<td>131A</td>
<td>196A</td>
<td>262A</td>
<td rowspan="2">working environment</td>
<td colspan="3">temperature</td>
<td colspan="8">0 ～ 40 ℃</td>
<td colspan="3">humidity</td>
<td colspan="8">20 ～ 90% RH</td>
<td colspan="4">Dimension W × H × D (mm)</td>
</tr>
<tr>
<td colspan="4">Weight (Kg)</td>
<td>310</td>
<td>360</td>
<td>500</td>
<td>620</td>
<td>810</td>
<td>1060</td>
<td>1350</td>
<td>1520</td>
</tr>
</tbody>
</table>
<p>3600 × 2000 × 10004800 × 2000 × 10006000 × 2000 × 1000</p>
<p>Programming function low (zero) voltage ride-through models, minimum response time 20msStep mode9999 stairstep Mode100 steps 999999 cycle gradient mode100 steps 999999 cycles start ramp time0.0 ～ 99.9 seconds online adjustment function under normal mode, the output voltage, and output frequency can be adjusted online, and the waveform can be switched online memory function power-down memory function, can remember the last output mode and parametersShortcut group10 groups in normal mode, 10 groups in harmonic sine voltage drop compensation0.000 ～ 0.500 EuroCommunication InterfaceRS232 (standard), RS485 (optional), GPIB (optional), Ethernet (optional), flip signal (standard)</p>
<table border="1" width="1000" cellspacing="0" cellpadding="0">
<colgroup>
<col span="4" />
<col span="4" /></colgroup>
<tbody>
<tr>
<td colspan="4">model</td>
<td>GS400T</td>
<td>GS500T</td>
<td>GS750T</td>
<td>GS1000T</td>
</tr>
<tr>
<td colspan="4">battery capacity</td>
<td>400kVA</td>
<td>500kVA</td>
<td>750kVA</td>
<td>1000kVA</td>
</tr>
<tr>
<td rowspan="3">AC input</td>
<td colspan="3">Phase</td>
<td colspan="4">Three-phase four-wire + PE</td>
</tr>
<tr>
<td colspan="3">Voltage</td>
<td colspan="4">Phase voltage: 220V ± 33V, line voltage: 380V ± 57V</td>
</tr>
<tr>
<td colspan="3">frequency</td>
<td colspan="4">50 / 60Hz ± 3Hz</td>
</tr>
<tr>
<td rowspan="26">AC output</td>
<td colspan="3">Phase</td>
<td colspan="4">Three-phase four-wire</td>
</tr>
<tr>
<td colspan="3">mode</td>
<td colspan="4">Three-phase standard mode, three-phase unbalanced mode</td>
</tr>
<tr>
<td colspan="3">Voltage</td>
<td colspan="4">Phase voltage: 0.0 ～ 300.0V</td>
</tr>
<tr>
<td colspan="3">frequency</td>
<td colspan="4">45.00 ～ 65.00Hz</td>
</tr>
<tr>
<td colspan="2">Rated current</td>
<td>220V</td>
<td>606A</td>
<td>757A</td>
<td>1136A</td>
<td>1515A</td>
</tr>
<tr>
<td colspan="2" rowspan="2">Setting accuracy</td>
<td>Voltage</td>
<td colspan="4">Resolution: 0.1V, accuracy: 0.4% × reading value + 0.4% × full-scale value</td>
</tr>
<tr>
<td>frequency</td>
<td colspan="4">Resolution: 0.01Hz, accuracy: 0.05%</td>
</tr>
<tr>
<td colspan="2" rowspan="4">measurement accuracy</td>
<td>Voltage</td>
<td colspan="4">Resolution: 0.1V, accuracy: 0.4% × reading value + 0.4% × full-scale value</td>
</tr>
<tr>
<td>frequency</td>
<td colspan="4">Resolution: 0.01Hz, accuracy: 0.05%</td>
</tr>
<tr>
<td>Current</td>
<td colspan="4">Resolution: 0.1A / 1A, accuracy: 0.4% × display value + 0.4% × rated output value</td>
</tr>
<tr>
<td>power</td>
<td colspan="4">Resolution: 0.1kW / 0.01kW / 0.001kW, accuracy: 0.7% × reading value + 0.7% × full-scale value</td>
</tr>
<tr>
<td colspan="3">Frequency stability</td>
<td colspan="4">≤0.02%</td>
</tr>
<tr>
<td colspan="3">Voltage distortion</td>
<td colspan="4">Linear load: THD ＜ 3%</td>
</tr>
<tr>
<td colspan="3">Transient recovery time</td>
<td colspan="4">20ms</td>
</tr>
<tr>
<td colspan="3" rowspan="2">Three-phase phase difference</td>
<td colspan="4" rowspan="2">Three-phase standard model: 120 ° ± 2 ° Three-phase unbalanced mode: 0.0 ° ～ 359.9 °, adjustable by 0.1 °</td>
</tr>
<tr>
<td colspan="3">Phase voltage crest factor</td>
<td colspan="4">1.41 ± 0.1</td>
</tr>
<tr>
<td colspan="3">Source voltage effect</td>
<td colspan="4">≤2%</td>
</tr>
<tr>
<td colspan="3">Load effect</td>
<td colspan="4">≤2%</td>
</tr>
<tr>
<td colspan="3" rowspan="2">Overload capacity</td>
<td colspan="4" rowspan="2">105% ＜ Output≤110% Shutdown output for 15 seconds; 110% ＜ Output≤200% Shutdown output for 5 seconds; 200% ＜ Output≤300% Shutdown output for 2 seconds; 300% ＜ Output immediately shut down the output.</td>
</tr>
<tr>
<td colspan="3" rowspan="2">Impact resistance</td>
<td colspan="4" rowspan="2">① It can withstand 3 times of rated current for 2S; ② It can withstand the starting impact of inductive load or crest factor of not more than 3.0 rectifier load with power, not more than 0.5 times the rated power of the power supply.</td>
</tr>
<tr>
<td colspan="3" rowspan="2">protective device</td>
<td colspan="4" rowspan="2">IGBT overheating, IGBT overcurrent, transformer overheating, input overvoltage, input under-voltage, output overvoltage, output under-voltage, output phase loss, output overcurrent, output overload, output short circuit, bus anti-recharge</td>
<td colspan="3">effectiveness</td>
<td colspan="4">＞ 86%</td>
<td rowspan="13">Features</td>
<td colspan="3">Display method</td>
<td colspan="4">8-inch LCD display, resolution: 800 * 600</td>
<td colspan="3">Output waveform</td>
<td colspan="4">Sine wave, harmonic (superimposed 2 ~ 40th harmonic)</td>
</tr>
<tr>
<td colspan="3">remote control</td>
<td colspan="4">Analog control port (optional)</td>
</tr>
<tr>
<td rowspan="2">DC output</td>
<td colspan="3">Voltage</td>
<td colspan="4">Actual DC bus voltage</td>
<td colspan="3">Current</td>
<td>436A</td>
<td>545A</td>
<td>818A</td>
<td>1091A</td>
<td rowspan="2">working environment</td>
<td colspan="3">temperature</td>
<td colspan="4">0 ～ 40 ℃</td>
<td colspan="3">humidity</td>
<td colspan="4">20 ～ 90% RH</td>
<td colspan="4">Dimension W × H × D (mm)</td>
</tr>
<tr>
<td colspan="4">Weight (Kg)</td>
<td>3050</td>
<td>3380</td>
<td>4870</td>
<td>6360</td>
</tr>
</tbody>
</table>
<p>The post <a rel="nofollow" href="https://technicalproducts.in/product/grid-simulator-analog-ac-power/">Grid simulator Analog AC Power</a> appeared first on <a rel="nofollow" href="https://technicalproducts.in">Technical Products</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://technicalproducts.in/product/grid-simulator-analog-ac-power/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Programmable Ac Power Supply 61 Series</title>
		<link>https://technicalproducts.in/product/programmable-ac-power-supply-61-series/</link>
					<comments>https://technicalproducts.in/product/programmable-ac-power-supply-61-series/#respond</comments>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Fri, 01 Jul 2022 08:27:17 +0000</pubDate>
				<guid isPermaLink="false">https://technicalproducts.in/?post_type=product&#038;p=7137</guid>

					<description><![CDATA[<p>The systems can be used to test PC/Servo/Telecom power supplies, adapters, chargers, backlight inverters, LED power drivers, UPS’s, PV Inverters, and EV chargers.</p>
<p>Input power： Single phase 200V±15%</p>
<p>Amplitude： DC15-1000Hz</p>
<p>Output power ：1500VA 3000VA 6000VA 500VA 1000VA 2000VA 4000VA</p>
<p>The post <a rel="nofollow" href="https://technicalproducts.in/product/programmable-ac-power-supply-61-series/">Programmable Ac Power Supply 61 Series</a> appeared first on <a rel="nofollow" href="https://technicalproducts.in">Technical Products</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Programmable Ac Power Supply 61 Series</p>
<p><strong>Input power：</strong> AC Single phase 200V±15%</p>
<p><strong>Amplitude</strong>： DC15-1000Hz</p>
<p><strong>Output power</strong> ：1500VA 3000VA 6000VA 500VA 1000VA 2000VA 4000VA</p>
<p>&nbsp;</p>
<div>
<table class="table table-bordered">
<tbody>
<tr>
<td width="120"><strong>Model</strong></td>
<td><strong>61500(F)</strong></td>
<td><strong>61501(F)</strong></td>
<td><strong>61502(F)</strong></td>
<td><strong>61504(F)</strong></td>
<td><strong>61800(F)</strong></td>
<td><strong>61801(F)</strong></td>
<td><strong>61802(F)</strong></td>
<td><strong>61804(F)</strong></td>
</tr>
<tr>
<td><strong>Output phase</strong></td>
<td>1</td>
<td>1</td>
<td>1</td>
<td>1</td>
<td>1</td>
<td>1</td>
<td>1</td>
<td>1</td>
</tr>
<tr>
<td><strong>Output power -AC power</strong></td>
<td>500VA</td>
<td>1000VA</td>
<td>2000VA</td>
<td>4000VA</td>
<td>500VA</td>
<td>1000VA</td>
<td>2000VA</td>
<td>4000VA</td>
</tr>
<tr>
<td><strong>amplitude/phase</strong></td>
<td colspan="8">150V/300V/Auto</td>
</tr>
<tr>
<td><strong>accuracy</strong></td>
<td colspan="8">0.2%+0.2%F.S.</td>
</tr>
<tr>
<td><strong>Resolution ratio</strong></td>
<td colspan="8">0.1V</td>
</tr>
<tr>
<td><strong>Degree of distortion</strong></td>
<td colspan="8">0.3% @ 50/60Hz</p>
<p>1% @ 15-1kHz</td>
</tr>
<tr>
<td><strong>source voltage effect features</strong></td>
<td colspan="8">0.1%</td>
</tr>
<tr>
<td><strong>Load effect features</strong></td>
<td colspan="8">0.2%</td>
</tr>
<tr>
<td><strong>Effective value(150V/300V)</strong></td>
<td>4A/2A</td>
<td>8A/4A</td>
<td>16A/8A</td>
<td>32A/20A</td>
<td>4A/2A</td>
<td>8A/4A</td>
<td>16A/8A</td>
<td>32A/20A</td>
</tr>
<tr>
<td><strong>Peak value</strong></td>
<td>24A/12A</td>
<td>48A/24A</td>
<td>96A/48A</td>
<td>192A/96A</td>
<td>24A/12A</td>
<td>48A/24A</td>
<td>96A/48A</td>
<td>192A/96A</td>
</tr>
<tr>
<td><strong>Amplitude</strong></td>
<td colspan="8">DC, 15 ~ 1kHz</td>
</tr>
<tr>
<td><strong>accuracy</strong></td>
<td colspan="8">0.15%</td>
</tr>
<tr>
<td><strong>Resolution ratio</strong></td>
<td colspan="8">0.1 Hz</td>
</tr>
<tr>
<td><strong>Power</strong></td>
<td>250W</td>
<td>500W</td>
<td>1000W</td>
<td>2000W</td>
<td>250W</td>
<td>500W</td>
<td>1000W</td>
<td>2000W</td>
</tr>
<tr>
<td><strong>Voltage</strong></td>
<td>212V/424V</td>
<td>212V/424V</td>
<td>212V/424V</td>
<td>212V/424V</td>
<td>212V/424V</td>
<td>212V/424V</td>
<td>212V/424V</td>
<td>212V/424V</td>
</tr>
<tr>
<td><strong>Current(212V/424V)</strong></td>
<td>2A/1A</td>
<td>4A/2A</td>
<td>8A/4A</td>
<td>16A/8A</td>
<td>2A/1A</td>
<td>4A/2A</td>
<td>8A/4A</td>
<td>16A/8A</td>
</tr>
<tr>
<td><strong>Amplitude</strong></td>
<td colspan="8">0Ω +200µH ~ 1Ω +1mH</td>
</tr>
<tr>
<td><strong>Bandwidth</strong></td>
<td>2400Hz</td>
<td>2400Hz</td>
<td>2400Hz</td>
<td>2400Hz</td>
<td>–</td>
<td>–</td>
<td>–</td>
<td>–</td>
</tr>
<tr>
<td><strong>Voltage amplitude</strong></td>
<td>90~250V,</p>
<p>1φ</td>
<td>90~250V,</p>
<p>1φ</td>
<td>90~250V,</p>
<p>1φ</td>
<td>190~250V,</p>
<p>3φ*3</td>
<td>90~250V,</p>
<p>1φ</td>
<td>90~250V,</p>
<p>1φ</td>
<td>90~250V,</p>
<p>1φ</td>
<td>190~250V,</p>
<p>3φ*3</td>
</tr>
<tr>
<td><strong>Rated frequency</strong></td>
<td colspan="8">47~63Hz</p>
<p>&nbsp;</td>
</tr>
<tr>
<td><strong>Current</strong><strong>（every term</strong><strong>）</strong></td>
<td>8A Max.</p>
<p>@90V</td>
<td>16A Max.</p>
<p>@90V</td>
<td>28A Max.</p>
<p>@90V</td>
<td>14A Max.</p>
<p>@190V</td>
<td>8A Max.</p>
<p>@90V</td>
<td>16A Max.</p>
<p>@90V</td>
<td>28A Max.</p>
<p>@90V</td>
<td>14A Max.</p>
<p>@190V</td>
</tr>
<tr>
<td><strong>Power factor</strong></td>
<td>0.97 Min.</td>
<td>0.97 Min.</td>
<td>0.97 Min.</td>
<td>0.98 Min.</td>
<td>0.97 Min.</td>
<td>0.97 Min.</td>
<td>0.97 Min.</td>
<td>0.98 Min.</td>
</tr>
<tr>
<td><strong>Amplitude</strong></td>
<td colspan="8">150V/300V</td>
</tr>
<tr>
<td><strong>Accuracy</strong></td>
<td colspan="8">0.2%+0.2%F.S.</td>
</tr>
<tr>
<td><strong>Resolution ratio</strong></td>
<td colspan="8">0.1V</td>
</tr>
<tr>
<td><strong>Amplitude(peak value)</strong></td>
<td>24A</td>
<td>48A</td>
<td>96A</td>
<td>192A</td>
<td>24A</td>
<td>48A</td>
<td>96A</td>
<td>192A</td>
</tr>
<tr>
<td><strong>Accuracy</strong><strong>（</strong><strong>effective</strong><strong>）</strong><strong>value</strong><strong>）</strong></td>
<td colspan="8">0.4%+0.3%F.S.</td>
</tr>
<tr>
<td><strong>Accuracy</strong><strong>（</strong><strong>peak value</strong><strong>）</strong></td>
<td colspan="8">0.4%+0.6%F.S.</td>
</tr>
<tr>
<td><strong>Accuracy</strong></td>
<td colspan="8">0.4%+0.4%F.S.</td>
</tr>
<tr>
<td><strong>Resolution ratio</strong></td>
<td colspan="8">0.1W</td>
</tr>
<tr>
<td><strong>Amplitude</strong></td>
<td>2~40 hypo-</td>
<td>2~40 hypo-</td>
<td>2~40 hypo-</td>
<td>2~40 hypo-</td>
<td>–</td>
<td>–</td>
<td>–</td>
<td>–</td>
</tr>
<tr>
<td><strong>Port</strong></td>
<td colspan="8">RS-232 (standard),GPIB(Optional)</td>
</tr>
<tr>
<td><strong>Running</strong></td>
<td colspan="8">0 ~ 40˚C / 30-90%RH</td>
</tr>
<tr>
<td><strong>Storage</strong></td>
<td colspan="8">-40 ~ +85˚C</td>
</tr>
<tr>
<td><strong>safety&amp;EMC</strong></td>
<td colspan="8">CE</td>
</tr>
<tr>
<td><strong>dimension</strong></p>
<p><strong>（</strong><strong>high*wide*deep</strong><strong>）</strong></td>
<td>134 x 483 x</p>
<p>610mm</td>
<td>134 x 483 x 610mm</td>
<td>134 x 483 x 610mm</td>
<td>268 x 483 x 610mm</td>
<td>134 x 483 x 610mm</td>
<td>134 x 483 x 610mm</td>
<td>134 x 483 x 610mm</td>
<td>268 x 483 x 610mm</td>
</tr>
<tr>
<td><strong>weight</strong></td>
<td>21kg</td>
<td>21kg</td>
<td>21kg</td>
<td>40kg</td>
<td>21kg</td>
<td>21kg</td>
<td>21kg</td>
<td>40kg</td>
</tr>
</tbody>
</table>
</div>
<p>&nbsp;</p>
<p><strong>The systems Ac Power Supply 61 Series can be used to test PC/Servo/Telecom power supplies, adapters, chargers, backlight inverters, LED power drivers, UPSs, PV Inverters, and EV chargers.</strong></p>
<div>
<table class="table table-bordered">
<tbody>
<tr>
<td><strong>Model</strong></td>
<td><strong>61700(F)</strong></p>
<p>&nbsp;</td>
<td><strong>61701(F)</strong></td>
<td><strong>61702(F)</strong></td>
</tr>
<tr>
<td><strong>Output phase</strong></td>
<td>3</td>
<td>3</td>
<td>3</td>
</tr>
<tr>
<td><strong>Output power -AC power</strong></td>
<td>1500VA</td>
<td>3000VA</td>
<td>6000VA</td>
</tr>
<tr>
<td><strong>Amplitude/phase</strong></td>
<td colspan="3">150V/300V/Auto</td>
</tr>
<tr>
<td><strong>Accuracy</strong></td>
<td colspan="3">0.2%+0.2%F.S.</td>
</tr>
<tr>
<td><strong>Resolution ratio</strong></td>
<td colspan="3">0.1V</td>
</tr>
<tr>
<td><strong>Degree of distortion</strong></td>
<td colspan="3">0.3% @ 50/60Hz</p>
<p>1% @ 15-1kHz</td>
</tr>
<tr>
<td><strong>Source voltage effect features</strong></td>
<td colspan="3">0.1%</td>
</tr>
<tr>
<td><strong>Load effect features</strong></td>
<td colspan="3">0.2%</td>
</tr>
<tr>
<td><strong>Effective value(150V/300V)</strong></td>
<td>4A/2A(150V/300V)</td>
<td>8A/4A(150V/300V)</td>
<td>16A/8A(150V/300V)</td>
</tr>
<tr>
<td><strong>Peak value</strong></td>
<td>24A/12A(150V/300V)</td>
<td>48A/24A(150V/300V)</td>
<td>96A/48A(150V/300V)</td>
</tr>
<tr>
<td><strong>Amplitude</strong></td>
<td colspan="3">15 ~ 1kHz</td>
</tr>
<tr>
<td><strong>Accuracy</strong></td>
<td colspan="3">0.15%</td>
</tr>
<tr>
<td><strong>Voltage amplitude</strong></td>
<td colspan="3">90 ~250V</td>
</tr>
<tr>
<td><strong>Frequency amplitude</strong></td>
<td colspan="3">47 ~63HZ</td>
</tr>
<tr>
<td><strong>Current</strong></td>
<td>8A Max</td>
<td>16A Max</td>
<td>28A Max</td>
</tr>
<tr>
<td><strong>Power factor</strong></td>
<td colspan="3">0.97Min</td>
</tr>
<tr>
<td><strong>Amplitude</strong></td>
<td colspan="3">150V/300v</td>
</tr>
<tr>
<td><strong>Resolution</strong></td>
<td colspan="3">0.1V</td>
</tr>
<tr>
<td><strong>Amplitude(peak value)</strong></td>
<td>24A</td>
<td>48A</td>
<td>96A</td>
</tr>
<tr>
<td><strong>Accuracy(effective value)</strong></td>
<td colspan="3">0.4%+0.3%F.S.</td>
</tr>
<tr>
<td><strong>Resolution</strong></td>
<td colspan="3">0.01A</td>
</tr>
<tr>
<td><strong>dimension</strong></p>
<p><strong>（</strong><strong>high*wide*deep</strong><strong>）</strong></td>
<td colspan="3">650 x515 x700mm</td>
</tr>
</tbody>
</table>
</div>
<p>The post <a rel="nofollow" href="https://technicalproducts.in/product/programmable-ac-power-supply-61-series/">Programmable Ac Power Supply 61 Series</a> appeared first on <a rel="nofollow" href="https://technicalproducts.in">Technical Products</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://technicalproducts.in/product/programmable-ac-power-supply-61-series/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>10S Series Solar Cell Analogue Power Supply</title>
		<link>https://technicalproducts.in/product/10s-series-solar-cell-analogue-power-supply/</link>
					<comments>https://technicalproducts.in/product/10s-series-solar-cell-analogue-power-supply/#respond</comments>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Fri, 01 Jul 2022 07:59:35 +0000</pubDate>
				<guid isPermaLink="false">https://technicalproducts.in/?post_type=product&#038;p=7123</guid>

					<description><![CDATA[<div class="elementor-element elementor-element-46e01ff elementor-widget elementor-widget-heading" data-id="46e01ff" data-element_type="widget" data-widget_type="heading.default">
<div class="elementor-widget-container">
<h4 class="elementor-heading-title elementor-size-medium">Features:</h4>
</div>
</div>
<div class="elementor-element elementor-element-93ac609 elementor-widget elementor-widget-text-editor" data-id="93ac609" data-element_type="widget" data-widget_type="text-editor.default">
<div class="elementor-widget-container">
<div class="elementor-text-editor elementor-clearfix">
<ol>
<li>  Voltage output: 0-300V &#38; 600V &#38; 1000V.</li>
<li>   3U15kw high power density, high power parallel operation and up to 1MW.</li>
<li>   Solar cell I-V curve simulation</li>
<li>  Simulate a variety of solar cell output characteristics (Fill Factor)</li>
<li>　I-V curve can be simulated under different temperature and illumination conditions.</li>
<li>　Test the Maximum Power Point Tracking (MPPT) ability and efficiency.</li>
<li>   Accurate voltage and current measurement.</li>
<li>   Serial output can be set to test the PV inverter operating voltage range.</li>
<li>   Standard RS232 port.</li>
<li>   Standard graphical PC operating software. Single operation available.</li>
<li>  High-brightness dot matrix VFD display.</li>
<li> High-frequency PWM and full-bridge conversion technology, high efficiency.</li>
<li> Strong current/power overload capacity, up to 110%.</li>
<li> Excellent output stability.</li>
<li> Lead drop compensation terminal for output lead at large current.</li>
<li> Complete protection for normal operation of power supply unit and load security.</li>
<li> LED segment display or color LCD. Brief, convenient for operation.</li>
<li> Serial/parallel output, convenient expansion.</li>
<li> Powerful programmable features to meet various testing needs.</li>
</ol>
</div>
</div>
</div>
<p>The post <a rel="nofollow" href="https://technicalproducts.in/product/10s-series-solar-cell-analogue-power-supply/">10S Series Solar Cell Analogue Power Supply</a> appeared first on <a rel="nofollow" href="https://technicalproducts.in">Technical Products</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The 10S series solar cell analog power supply is an attractive, compact, high-performance, powerful, and easy-to-operate DC programmable power supply with an I-V simulation curve, fast response, controllable, repeatable, stable, and accurate, with a built-in SAS model for the setting of Voc, Isc, Vmp and Imp parameters to generate and output I-V curve. Moreover, solar cell parameters or a set of 1024 points of V&amp;I data can be edited via the PC software and then downloaded to the power supply, high-power, small size, fast transient response, low ripple, high precision, good performance, with indicators reaching the international advanced level.</p>
<div class="elementor-element elementor-element-46e01ff elementor-widget elementor-widget-heading" data-id="46e01ff" data-element_type="widget" data-widget_type="heading.default">
<div class="elementor-widget-container">
<h4 class="elementor-heading-title elementor-size-medium">Features of 10S Series Solar Cell analog power supply</h4>
</div>
</div>
<div class="elementor-element elementor-element-93ac609 elementor-widget elementor-widget-text-editor" data-id="93ac609" data-element_type="widget" data-widget_type="text-editor.default">
<div class="elementor-widget-container">
<div class="elementor-text-editor elementor-clearfix">
<ol>
<li> Voltage output: 0-300V &amp; 600V &amp; 1000V.</li>
<li> 3U15kw high power density, high power parallel operation, and up to 1MW.</li>
<li> Solar cell I-V curve simulation</li>
<li> Simulate a variety of solar cell output characteristics (Fill Factor)</li>
<li> I-V curve can be simulated under different temperature and illumination conditions.</li>
<li> Test the Maximum Power Point Tracking (MPPT) ability and efficiency.</li>
<li>  Accurate voltage and current measurement.</li>
<li> Serial output can be set to test the PV inverter operating voltage range.</li>
<li> Standard RS232 port.</li>
<li> Standard graphical PC operating software. Single operation available.</li>
<li> High-brightness dot matrix VFD display.</li>
<li> High-frequency PWM and full-bridge conversion technology, high efficiency.</li>
<li> Strong current/power overload capacity, up to 110%.</li>
<li> Excellent output stability.</li>
<li> Lead drop compensation terminal for output lead at large current.</li>
<li> Complete protection for normal operation of power supply unit and load security.</li>
<li> LED segment display or color LCD. Brief, convenient for operation.</li>
<li> Serial/parallel output, convenient expansion.</li>
<li> Powerful programmable features to meet various testing needs.</li>
</ol>
</div>
</div>
</div>
<p>&nbsp;</p>
<div>
<table class="table table-bordered" style="height: 1327px;" width="808">
<tbody>
<tr>
<td colspan="2"><strong>Model</strong></td>
<td><strong>50805(F)</strong></td>
<td><strong>50810(F)</strong></td>
</tr>
<tr>
<td colspan="2"><strong>Input</strong></td>
<td colspan="2">3-phase,3-line<br />
380V±40V，50Hz±5Hz</td>
</tr>
<tr>
<td rowspan="3"><strong>Output</strong></td>
<td>Voltage</td>
<td colspan="2">0-630V</td>
</tr>
<tr>
<td>Current</td>
<td>0-25A</td>
<td>0-50A</td>
</tr>
<tr>
<td>Power</td>
<td>0-15kVA</td>
<td>0-30kVA</td>
</tr>
<tr>
<td><strong>Display</strong></td>
<td></td>
<td colspan="2">LCD,4 digits</td>
</tr>
<tr>
<td rowspan="2"><strong>Setting Accuracy</strong></td>
<td>Voltage</td>
<td colspan="2">(100V-630V):≤±1%*reading<br />
(6V-100V):≤±1%*reading±1V</td>
</tr>
<tr>
<td>Current</td>
<td colspan="2">≤±1% (reading+measurement)</td>
</tr>
<tr>
<td rowspan="2"><strong>Read Back Accuracy</strong></td>
<td>Voltage</td>
<td colspan="2">(100V-630V):≤±1%*reading<br />
(6V-100V):≤±1%*reading±1V</td>
</tr>
<tr>
<td>Current</td>
<td colspan="2">≤±1% (reading+measurement)</td>
</tr>
<tr>
<td rowspan="2"><strong>Ripple&amp;Noise<br />
20Hz-20MHz</strong></td>
<td>Vrms</td>
<td colspan="2">350mV</td>
</tr>
<tr>
<td>Vpp</td>
<td colspan="2">900mV</td>
</tr>
<tr>
<td colspan="2"><strong>Power Voltage Effect</strong></td>
<td colspan="2">±0.2%</td>
</tr>
<tr>
<td colspan="2"><strong>Load Effect</strong></td>
<td colspan="2">±0.2%</td>
</tr>
<tr>
<td colspan="2"><strong>Noise</strong></td>
<td>≤65db(A)</td>
<td>≤70db(A)</td>
</tr>
<tr>
<td colspan="2"><strong>Efficiency</strong></td>
<td colspan="2">≥ 0.85</td>
</tr>
<tr>
<td colspan="2"><strong>Overload</strong></td>
<td colspan="2">105%200%&lt; rated current, the output will be stopped immediately</td>
</tr>
<tr>
<td colspan="2"><strong>Protection Function</strong></td>
<td colspan="2">Input lack phase protection(three-phase);<br />
Output over-current/over-voltage protection; inverted and short circuit protection;<br />
Overheat protection</td>
</tr>
<tr>
<td colspan="2"><strong>Transient Response Time</strong></td>
<td colspan="2">≤10ms</td>
</tr>
<tr>
<td colspan="2"><strong>Max. Lead Wire Voltage Drop Compensation</strong></td>
<td colspan="2">15V</td>
</tr>
<tr>
<td colspan="2"><strong>Communication Function</strong></td>
<td colspan="2">RS232(standard)/RS485(Optional)</td>
</tr>
<tr>
<td colspan="2"><strong>Memory Function</strong></td>
<td colspan="2">Can preset 10 groups parameters</td>
</tr>
<tr>
<td colspan="2"><strong>Measurement Function</strong></td>
<td colspan="2">5 setting groups and 10 steps sequence,3 working modes for every step, max cycle3000 times</td>
</tr>
<tr>
<td colspan="2"><strong>Temperature Drifts</strong></td>
<td colspan="2">0.04%Vmax/℃</td>
</tr>
<tr>
<td colspan="2"><strong>Time Drifts</strong></td>
<td colspan="2">0.3%Vmax</td>
</tr>
<tr>
<td colspan="2"><strong>Working Conditions</strong></td>
<td colspan="2">Operating Temperature:0℃-40℃; Operating Humidity:10-95%</td>
</tr>
<tr>
<td colspan="2"><strong>Dimension<br />
W×H×D(mm)</strong></td>
<td colspan="2">550×1200×660</td>
</tr>
<tr>
<td colspan="2"><strong>Weight</strong></td>
<td colspan="2">240kg</td>
</tr>
<tr>
<td colspan="2">Remarks</td>
<td colspan="2">Programmable and reading accuracy condition:(25℃±5℃)<br />
Load change from 100% to 5%or 50% to 100%, the time for output voltage returning to “rated value ±100mV”<br />
Temperautredrifts: output voltage change rate is caused by temperature change under power supply using condition<br />
Time drifts: output voltage change rate is caused by working more than 8 hours</td>
</tr>
</tbody>
</table>
</div>
<p>The post <a rel="nofollow" href="https://technicalproducts.in/product/10s-series-solar-cell-analogue-power-supply/">10S Series Solar Cell Analogue Power Supply</a> appeared first on <a rel="nofollow" href="https://technicalproducts.in">Technical Products</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://technicalproducts.in/product/10s-series-solar-cell-analogue-power-supply/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
	</channel>
</rss>