Product Description
The 10S series solar cell analog power supply is an attractive, compact, high-performance, powerful, and easy-to-operate DC programmable power supply with an I-V simulation curve, fast response, controllable, repeatable, stable, and accurate, with a built-in SAS model for the setting of Voc, Isc, Vmp and Imp parameters to generate and output I-V curve. Moreover, solar cell parameters or a set of 1024 points of V&I data can be edited via the PC software and then downloaded to the power supply, high-power, small size, fast transient response, low ripple, high precision, good performance, with indicators reaching the international advanced level.
Model | 50805(F) | 50810(F) | |
Input | 3-phase,3-line 380V±40V,50Hz±5Hz | ||
Output | Voltage | 0-630V | |
Current | 0-25A | 0-50A | |
Power | 0-15kVA | 0-30kVA | |
Display | LCD,4 digits | ||
Setting Accuracy | Voltage | (100V-630V):≤±1%*reading (6V-100V):≤±1%*reading±1V | |
Current | ≤±1% (reading+measurement) | ||
Read Back Accuracy | Voltage | (100V-630V):≤±1%*reading (6V-100V):≤±1%*reading±1V | |
Current | ≤±1% (reading+measurement) | ||
Ripple&Noise 20Hz-20MHz | Vrms | 350mV | |
Vpp | 900mV | ||
Power Voltage Effect | ±0.2% | ||
Load Effect | ±0.2% | ||
Noise | ≤65db(A) | ≤70db(A) | |
Efficiency | ≥ 0.85 | ||
Overload | 105%200%< rated current, the output will be stopped immediately | ||
Protection Function | Input lack phase protection(three-phase); Output over-current/over-voltage protection; inverted and short circuit protection; Overheat protection | ||
Transient Response Time | ≤10ms | ||
Max. Lead Wire Voltage Drop Compensation | 15V | ||
Communication Function | RS232(standard)/RS485(Optional) | ||
Memory Function | Can preset 10 groups parameters | ||
Measurement Function | 5 setting groups and 10 steps sequence,3 working modes for every step, max cycle3000 times | ||
Temperature Drifts | 0.04%Vmax/℃ | ||
Time Drifts | 0.3%Vmax | ||
Working Conditions | Operating Temperature:0℃-40℃; Operating Humidity:10-95% | ||
Dimension W×H×D(mm) | 550×1200×660 | ||
Weight | 240kg | ||
Remarks | Programmable and reading accuracy condition:(25℃±5℃) Load change from 100% to 5%or 50% to 100%, the time for output voltage returning to “rated value ±100mV” Temperautredrifts: output voltage change rate is caused by temperature change under power supply using condition Time drifts: output voltage change rate is caused by working more than 8 hours |
Reviews
There are no reviews yet.